Please Note:Â
- Parallel connections are not supported
Features
Single Phase Operation: 1-phase operation for PV input.
High Efficiency: Up to 98% DC to AC conversion efficiency.
Pure Sine Wave Output: Ensures clean power output.
Wide MPPT Voltage Range: 60VDC to 450VDC.
Multiple Communication Ports: RS232, RS485, WIFI, GPRS, Lithium battery interface.
Supports Dual Load Output: Can handle two separate load outputs.
Auto Restart and Start-up Voltage: Automatically restarts and supports specified start-up voltages.
Specifications
PV Input (DC)
Maximum PV Input Power: 6500W
Nominal DC Voltage/Maximum DC Voltage: 360VDC/500VDC
Start-up Voltage / Initial Feeding Voltage: 60VDC/90VDC
MPPT Voltage Range: 60VDC to 450VDC
Maximum Input Current: 1/22A
Grid Output (AC)
Rated Output Power: 6200W/6200VA
Nominal Output Voltage: 220/230/240VAC
Output Voltage Range: 195.5V to 253VAC
Nominal Output Current: 27.0A
Power Factor: >0.99
Maximum Conversion Efficiency (DC/AC): 98%
Battery Mode Output (AC)
Nominal Output Voltage: 220/230/240VAC
Output Waveform: Pure sine wave
Efficiency (DC to AC): 94%
AC Input
AC Start-up Voltage / Auto Restart Voltage: 120-140VAC/180VAC
Acceptable Input Voltage Range: 90-280VAC or 170-280VAC
Maximum AC Input Current: 40A
Maximum AC Charging Current: 40A
Physical Dimensions
420mm x 350mm x 110mm
500mm x 415mm x 180mm
Net Weight: 8.0kg / 8.9kg
Gross Weight: 9.0kg / 10.0kg
Environment
Operating Temperature: -10°C to 50°C
Humidity: 5% to 95% Relative Humidity (Non-condensing)
Battery & Charger
Nominal DC Voltage: 48VDC
Maximum Solar Charging Current: 120A
Maximum AC Charging Current: 100A
Maximum Solar+AC Charging Current: 120A
Communication Port
Available Ports: RS232/RS485/WIFI/GPRS/LITHIUM BATTERY
Two-Load Output Power
Full Load: 2067W
Maximum Main Load: 6200W
Maximum Second Load (battery mode): 2067W
Maximum Load Cut Off Voltage: 52VDC
Maximum Load Return Voltage: 54VDC
Compliance and Standards
Safety: CE Standard Compliance
Warranties:
1 Year Repair Warranty
All inverters and batteries must be installed by a qualified electrical wireman or Master electrician with a valid registration with the Department of Labour. A valid electrical certificate of compliance (COC) must be issued once installed, specific to the installation of the backup or solar system. Any warranty claim submitted without installation photos, a valid COC and proof of a qualified wireman/master electrician installing the unit, can be rejected and will render the warranty claim null at void.